A. outside top exhaust, Attach mounting plate to wall, Outside top exhaust –14 – GE DE68-02957A User Manual
Page 12: Outside top exhaust, Installation instructions, Attach the mounting plate to the wall a1. 12, Vertical duct), Installation overview
Place the mounting plate against the wall and
insert the toggle wings into the holes in the wall
to mount the plate.
NOTE:
Before tightening the toggle bolts and the
wood screw(s), check again to be sure that the
mounting plate is level and centered left to right.
CAUTION:
Be careful to avoid pinching fingers
between the back of the mounting plate and the wall.
Tighten all bolts. Pull the plate away from the
wall to help tighten the bolts. Be careful not to
over-torque the toggle bolts.
3
A
4
ATTACH THE MOUNTING
PLATE TO THE WALL
A1.
12
OUTSIDE TOP EXHAUST
(Vertical Duct)
Remove the template from the rear wall. The
mounting plate must be secured to the wall using at
least 3 toggle bolts and one wood screw. The wood
screw must engage a wall stud.
Remove the toggle wings from the bolts.
Insert the bolts into the mounting plate
through the holes designated to go into drywall
and reattach the toggle wings to
3
⁄
4
″ onto each bolt.
1
INSTALLATION OVERVIEW
A1.
Attach Mounting Plate to Wall
A2.
Prepare Top Cabinet
A3.
Check Damper Operation
A4.
Mount Microwave Oven
A5.
Adjust Exhaust Adaptor
A6.
Connect Ductwork
Wall
Mounting
Plate
Spacing for Toggles
More Than Wall
Thickness
Bolt End
Toggle
Bolt
Toggle Wings
To use toggle bolts:
Installation Instructions
2