Receptacles – Generac SVP5000 97193 User Manual
Page 8
Generac Portable Products SVP5000 Generator
8
RECEPTACLES
120 Volt AC, 20 Amp Duplex
Receptacles
Each of these receptacles is protected against
overload by 20 Amp push-to-reset circuit breaker.
Use each receptacle to operate 120 Volt, 60 Hz, single
phase loads requiring up to 2,400 (2.4kW) watts of
power at 20 Amps of current (Figure 7).
120/240 Volt AC, 20 Amp Locking
Receptacle
Use a NEMA L14-20P plug with this receptacle.
Connect a 4-wire cord set rated for 250 Volt loads at
20 AC Amps (or greater) (Figure 8). You can use the
same 4-wire cord if you plan only to run a 120 Volt
load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads and is protected by a 20 Amp push-to-
reset circuit breaker.
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5-30P plug with this receptacle.
Connect a 3-wire cord set rated for 125 Volt AC loads
at 30 Amps to the plug (Figure 9).
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3,600 watts
(3.6 kW) of power at 30 Amps. The outlet is protected
by a 30 Amp push-to-reset circuit breaker.
Figure 9 120 Volt, 30 Amp Locking Receptacle
Figure 7 120 Volt, 20 Amp Duplex Receptacle
Figure 8 120/240 Volt, 20 Amp Locking Receptacle