beautypg.com

Global Machinery Company GEN800 User Manual

Page 13

background image

13

and disconnected. It is best to always use a voltage or surge

protector with this generator.

It is NOT recommended to

connect any electronic equipment to the generator such

as computers, televisions, or stereo equipment. They

are very sensitive to the input supply fluctuations and

could be damaged if run off this generator. This warning

also includes caravans where electronic equipment is

incorporated as part of the wiring.

AC and DC overload cut out

IMPORTANT:

Exceeding the rated capacity of your

generator can result in serious damage to your generator

and connected apparatus.
1. Each receptacle has a circuit breaker to protect the

generator from over loading.

2. If the circuit breaker trips, unplug all electrical apparatus

from the generator.

3. Let the overload cut out switch cool down.
4. If it is an AC apparatus causing the overload push the AC

circuit breaker button (11). If it is a DC apparatus causing

the overload push the DC circuit breaker button (14).

Commence to start your generator accordingly.

5. When re connecting appliances, reduce the load to that

which previously overloaded the generator.

Periodic maintenance

Items

Remarks

Every 50hrs

or every

month

Every 150

hrs or every

month

Spark Plug Remove

Carbon

x

Air Filter

Cleaning

x

Fuel Filters Clean

x

Decarbon-

isation

Clean

x

Generator maintenance

Your generator should be kept clean and dry at all times.

The generator should not be stored or operated in environments

that includes excessive moisture, dust or any corrosive vapours.

If these substances are on the generator, clean with a cloth or

soft bristle brush. Do not use a garden hose or anything with

water pressure to clean the generator. Water may enter the

cooling air slots and could possibly damage the rotor, stator and

the internal windings of the generator head.

Storage

If you are going to store your generator for more than

30 days, use the following information as a guide to

prepare the generator for storage.

Never store generator with

fuel in the tank indoors or in

enclosed, poorly ventilated

areas, where fumes can reach

an open flame, spark or pilot

light as on a furnace, water

heater, clothes dryer or other

gas appliances.

Spark plugs

1. Remove spark plug from the generator with a spark plug

spanner socket.

2. Remove carbon deposits using a wire brush.
3. Check for discoloration on the top of the spark plug. The

standard colour should be a tan colour.

4. Check the spark plug gap. The acceptable gap should be

between 0.7 – 0.8mm.