All On/All Off
Depending upon your primary controller, the 45602 lamp
module can be set to respond to

ALL ON and ALL OFF

commands in up to four different ways. Some controllers
may not be able to change the response from its default
setting. Please refer to your controller’s instructions for
information on whether or not it supports the configuration
function and if so, how to change this setting.
The four possible responses are:

- It will respond to

ALL ON and the ALL OFF

commands (default).

- It will not respond to

ALL ON or ALL OFF commands.

- It will respond to the

ALL OFF command but will not respond

to the

ALL ON command.

- It will respond to the

ALL ON command but will not respond

to the

ALL OFF command.

Load Sensing
Load sensing is disabled when shipped from the factory. This
feature can be enabled if desired. Setting parameter 29 to a
value of 1 will enable the Load Sense function.

- Parameter No: 29
- Length: 1 Byte
- Valid Values = 0 or 1 (default 0)

Note: When replacing a burned-out light bulb, the load sensing
feature (if enabled) will automatically turn the light

ON when the new

bulb is installed even if the Z-wave module was previously turned

OFF.