P 8

8

M A I N T E N A N C E

The GOLDMUND SRM250 amplifier usually requires no maintenance.

Always turn the power off before cleaning your amplifier. Use only a clean, soft, damp
cloth. Dampen with water or a mild detergent solution. Avoid abrasive or harsh cleansers
(eg. products containing sodium carbonate).

T E C H N I C A L D ATA

P O W E R

• Nominal power before clipping: 200 W RMS (2 - 8 Ohms).

120 W RMS (1 - 16 Ohms).

• Maximum power: > 400 W RMS (3 Ohms).

• Maximum voltage: 55 V peak. Maximum current : > 15 A peak.

• Maximum current: > 15 A peak.

F R E Q U E N C Y R E S P O N S E

These figures are valid for the circuit alone, at any level between 0 and nominal power.

• +/- 0.1 dB, 10 Hz - 1 MHz.

• +/- 1 dB, 6 Hz - 1.2 MHz.

• +/- 3 dB, 3 Hz - 1.4 MHz.

A N A L O G U E I N P U T S E N S I T I V I T Y

• Nominal level: 0.75 V.

• Input impedance: 50 kOhms.

G R O U P D E L AY

Propagation delay < 100 ns stable with frequency from DC to 200 kHz.

9