– GE Monogram 36" Professional Gas Cooktop with

4 Burners and Griddle

Specification Revised 10/05

130440

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

GEAppliances.com or call GE Answer Center

®

service, 800.626.2000.

Backsplash Accessories

The cooktop requires a 12" minimum clearance to a vertical

combustible surface at the rear. A backsplash is required

for installations with less than 12" clearance. The following

backsplash accessories are available, or a custom,

non-combustible backsplash can be used.
ZX12B36HSS, 12" backsplash
ZX22B36HSS, 22" backsplash with warming shelf

Backsplash with Warming Shelf

All Monogram

®

Professional Hoods feature infrared warming lights.

The 22"-high backsplash accessory with warming shelf is a perfect

complement when installed with the tapered or straight-sided hoods.
• Restaurant-Style Professional Hoods are shipped with a stainless

steel backsplash and warming shelf.

Side View with a Backsplash

22" High

Backsplash

with Shelf

26-5/8"

12"

36" Min.

to Combustibles

9-1/2"

3/4"

22"

12" High Backsplash

36" Min.

to

Combustibles

0" Clearance

12" Min. to Combustibles or

0" Min. to Combustibles

with 12" or 22" Backsplash

Advance Planning for 36"

Professional Cooktops

Professional cooktops offer a number of choices in size and cooktop

configurations.
• All Professional cooktops are factory set for natural or liquid

propane gas. The correct model should be ordered for the

installation situation.

Note: Conversion kits (WB49X10132, Nat. to LP and WB49X10133,

LP to Nat.) are available if the wrong gas type was ordered. High

Altitude kit, WB49X10130, is also available. The kits must be installed

by a qualified service technician at additional cost.

Electrical Requirements

Cooktops must be supplied with 120V, 60Hz, and connected to an

individual, properly grounded branch circuit protected by a 15 amp

circuit breaker or time-delay fuse.
Gas Supply

• Natural gas models are designed to operate at 5" water column

pressure. A regulator is required at the natural gas source to provide

maximum of 7" water pressure to the cooktop regulator.

• The liquid propane models are designed to operate at 10" water

column pressure. A regulator is required at the LP source to provide

maximum of 14" water pressure to the cooktop regulator.

605Dia84

7"

2"

Locate gas

inlet on

back wall

or on floor

2" from

back wall

16"