4

3.0L GAS eNGINe SeRVICe ReCoMMeNdATIoNS

Maintenance Tasks

Level 1

Level 2

Level 3

Level 4

Recommended to

be done monthly/

10 hrs.

Task

Comp.

(Date-

Initials)

Required to be

done 3 months/

Break-in /30 hrs.

Task

Comp.

(Date-

Initials)

Required to

be done Semi-

Annually/50 hrs.

Task

Comp.

(Date-

Initials)

Required to be done

Annually/ 100 hrs.

Task

Comp.

(Date-

Initials)

1. Disable the unit from operating

per the first page warning.

2. Check the engine oil level. Adjust

as necessary.

3. Check the engine coolant level.

Adjust as necessary.

4. Check the engine coolant ther-

mal protection level. Correct as
necessary.

5. Check the natural gas delivery

system on gas engine driven
units. Tighten connections as
necessary.

6. Check the diesel fuel supply

level for diesel engine driven
units. Fill as necessary.

7. Drain water and sediment from

the diesel fuel tank on diesel
engine driven units.

8. Drain water from the fuel line

water separator on diesel
engine driven units if the unit is
equipped with one.

9. Check the air inlets and outlets

for debris. Clean as necessary.

10. Check the battery electrolyte

level if accessible. Adjust as
necessary.

11. Check the battery posts,

cables, and charger for loose
connections, corrosion, and
proper operation. Correct as
necessary.

12. Check the unit wiring for loose

connections, corrosion, and
damage. Correct as necessary.

13. Check the engine accessory

drive belts for wear, weather
cracking, and damage. Replace
as necessary.