6 power supply cord, 7 ground fault circuit interrupters – Guardian Technologies 02010-2 User Manual
Page 35
33
2.7.6 POWER
SUPPLY CORD
The power supply cord must comply with all appli-
cable codes, standards and regulations. It must be
large enough to handle the full amperage to which it
will be subjected.
2.7.7 GROUND FAULT CIRCUIT INTERRUPTERS
The National Electrical Code (NFPA 70, 551-7)
requires that ground fault circuit interrupters (GFCIs)
on all external and some internal electrical recepta-
cles be installed. Contact the manufacturer or dealer
for recommendations.
Section 2 – Installation
Recreational Vehicle Generator
Figure 2.18 – Transfer Switch Isolation Method
PRIMEPACT
RV Service Locator 1-800-333-1322 • www.guardiangenerators.com
•
Maintenance Schedule
Check engine oil level
Change oil
Change oil filter
Clean & re-oil foam pre cleaner
Clean air intake
Clean & reset spark plugs
Replace fuel filter
Inspect battery posts & cables
“Exercise” generator
Every 8 hours
or before use
Every 25 hours
or 3 months
Every 100 hours
or once a year
•
•
•
•
•
•
•
•
Figure 2.19 – Installation With Isolation Receptacle
PRIMEPACT
RV Service Locator 1-800-333-1322 • www.guardiangenerators.com
•
Maintenance Schedule
Check engine oil level
Change oil
Change oil filter
Clean & re-oil foam pre cleaner
Clean air intake
Clean & reset spark plugs
Replace fuel filter
Inspect battery posts & cables
“Exercise” generator
Every 8 hours
or before use
Every 25 hours
or 3 months
Every 100 hours
or once a year
•
•
•
•
•
•
•
•