SERVICING INSTRUCTIONS

SERVICING / FAULT FINDING CHARTS

NO

SPARK

IGNITION

FUNCTIONAL

CHECK

2

Ensure

there

is

no

debris

around

the

pilot

assembly,

(e.g.

coal,

soot

etc.)

which

could

short

the

spark,

clear

the

area.

From

Ignition

Fault

Finding

Chart

Part

1.

Consult

the

Users

Instructions,

retry.

Operate

the

valve

to

light

the

pilot,

does

the

valve

‘click’?

Is

the

valve

being

operated

properly?

Is

the

pilot

burner

horizontal?

See

diagram

1

on

page

15.

Reset

the

electrode

gap,

retry.

Replace

the

pilot

unit.

Replace

the

electrode

lead

and

retry.

Remove

the

electrode

lead

from

electrode

with

insulated

pliers.

Hold

the

tip

4mm

from

the

pilot

pipework,

is

there

a

spark

when

the

valve

‘clicks’?

Check

the

defective

or

damaged

control

knob

spindle

or

cam

operation.

Check

for

correct

location

of

piezo

components.

Correct

and

retry.

Is

the

electrode

wire

detached

from

the

piezo

in

the

valve?

Replace

the

combined

lead,

retry.

Remove

the

electrode

lead

from

the

piezo.

Operate

the

valve.

Does

a

spark

jump

from

the

piezo

to

the

valve

body?

Has

ignition

lead

become

detached

or

is

connection

poor?

Correct

and

retry.

NO

NO

YES

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

YES

PILOT

WILL

NOT

STAY

LIT

OR

FIRE

GOES

OUT

IN

USE

SYSTEM

OK

FLAME

FAILURE

FUNCTIONAL

CHECK

3

Ensure

there

is

no

debris

around

the

pilot

assembly,

(e.g.

coal,

soot

etc.)

which

could

short

the

spark,

clear

the

area.

Light

the

pilot

and

keep

the

control

knob

pushed

in

at

least

10

seconds

before

letting

go.

With

the

pilot

running,

is

the

gas

pressure

stated

on

the

databadge?

With

the

fire

running

on

full,

is

the

gas

at

the

pressure

stated

on

the

databadge?

Run

for

no

more

than

60

seconds,

turn

off,

time

interval

until

mag

unit

shuts

with

a

click.

Is

this

greater

than

7

seconds?

Tighten

the

connection

and

retry.

Run

for

60

seconds,

turn

off,

time

interval

until

mag

unit

shuts

with

a

click.

Is

this

greater

than

7

seconds?

Will

the

pilot

stay

lit?

Is

thermocouple

connection

good

in

back

of

valve?

Replace

the

thermocouple.

Will

pilot

stay

alight?

Change

the

pilot

unit.

Change

mag

unit.

Is

the

pilot

flame

of

the

correct

length?

See

diagram

1

on

page

19.

Problem

is

with

the

pipework

or

fittings

which

lead

to

the

fire.

Correct

and

retry.