User instructions, Running the appliance – Stovax Stockton 7161 User Manual
Page 3
Open stacking allows oxygen to easily reach every part of
the fire.
Compact stacking will make the wood burn slower as wood
can only reach the outside of the fire. This will cause the
fire to smoulder and produce smoke.
5.2 Experience establishes settings to suit personal preferences.
5.3 Do not burn large amounts of fuel with the Airwash con-
trol
closed for long periods of time. This reduces the glass
cleaning effect and causes tars and creosotes to build-up in
the appliance and flue system and will produce excessive
amounts of smoke.
5.4 When in use, burning the appliance at high output for a
short period also reduces tars and creosote.
When running the appliance:
• Burn new logs at high output for a few minutes before
adjusting the Airwash control.
Refuel little and often for clean, efficient burning.
A bright and clean firebox indicates the appliance is
burning well.
• Add a small amount of kindling and open the air controls
if the firebed is low when the appliance is refuelled
This helps re-establish the fire. Do not close the air controls
until the fire is burning well.
5.5 burning solid fuel:
To burn solid fuel efficiently in a wood version the multi-
fuel kit should be fitted.
Multi-fuel kit part numbers:
Appliance
Part No.
Stockton 5
7108
Only for use with recommended fuels, see Installation
section
for full fitting details.
• Set air controls, Diagram 6
PR8006
Airwash: 50%
Airwash: 50%
PR8004
Air Inlets
Log Guard
• Close the door fully
5. RuNNING The APPlIANce
5.1 burning wood:
• Close the Primary air control and use the Airwash to
control the burn rate when appliance is at operating
temperature, Diagram 4
PR8005
Airwash: Adjust
• Wood burns best on a bed of ash
• Rake the embers evenly over the fire bed and open the
Airwash control
fully for a few minutes before re-fuelling to
establish a glowing bed of coals
• Stack the logs in an open arrangement, Diagram 5
Compact Stacking
Open Stacking
3