15

AC and DC overload cut out

IMPORTANT.

Exceeding the rated capacity of your

generator can result in serious damage to your generator

and connected apparatus.
1. Each separate circuit has a circuit breaker to protect the

generator from over loading.

2. If the circuit breaker trips, unplug all electrical apparatus

from the generator.

3. Let the overload cut out switch cool down.
4. If it is an AC apparatus causing the overload push the

AC reset button (3). If it is the DC apparatus press the

DC reset button (4). Commence to start your generator

accordingly.

5. When re connecting appliances, reduce the load to that

which previously overloaded the generator.

Note.

If the DC overload cut out has operated, and the

240V is being used at the same time, reduce or remove

the 240V appliance from the generator. This will reduce the

output current on the DC circuit.

Generator maintenance

Your generator should be kept clean and dry at all times.

The generator should not be stored or operated in

environments that includes excessive moisture, dust or any

corrosive vapours. If these substances are on the generator,

clean with a cloth or soft bristle brush. Do not use a garden

hose or anything with water pressure to clean the generator.

Water may enter the cooling air slots and could possibly

damage the rotor, stator and the internal windings of the

generator head.

Storage

If you are going to store your generator for more than 30

days, use the following information as a guide to prepare

the generator for storage.
Never store generator with fuel in the tank indoors or in

enclosed, poorly ventilated areas, where fumes can reach

an open flame, spark or pilot light as on a furnace, water

heater, clothes dryer or other gas appliances.

Always drain the generator; tank and fuel system by

opening the small drain valve (14) in the lower section of

the carburetor bowl before storing.

Spark plugs

1. Remove spark plug (13) from the generator with the

spark plug spanner socket supplied.

2. Remove carbon deposits using a wire brush.
3. Check for discoloration on the top of the spark plug.

The standard colour should be a tan colour.

4. Check the spark plug gap. The acceptable gap should

be between 0.7–0.8mm.

5. The recommended spark plugs are as follows:

Sino E6TC (Original one supplied in unit)

NKG-BP6HS

Engine oil replacement

1. Place the generator on a level surface and warm up the

engine for several minutes. The stop the engine.

2. Remove oil filler cap (5).
3. Place an oil pan under the generator and commence

removing the oil drain cock (9) so that the oil can be

completely drained.

4. Check the oil drain cock (9), gasket, oil filler cap (5) and

O-ring. If damaged, have these replaced.

5. Reinstall the oil drain cock (9).
6. Add engine oil to the upper level. Recommended

4 stroke engine oil is SAE #30. Refer to the “

Checking

the engine oil

” section in this instruction manual.

CAUTION.

Check that no foreign material, debris, dust

enters the crankcase.

0.7– 0.8mm (0.028”– 0.031”)