Vert-I-Pak Installation Recommendations

For proper unit performance and maximum operating life please refer to the minimum installation clearances below.

The above suggestions are for reference only and do not represent all possible installations. Please contact the factory
for information regarding affects of other installation arrangements.

By following these simple recommendations you can be confi dent that your Friedrich Vert-I-Pak

®

will provide years

of worry-free operation.

Fig ure 2

Fig ure 1

Any time obstructions are present use
the following guidelines for proper
spacing from the VERT-I-PAK louver:

• For minor obstructions such as lamp

poles or small shrubbery a clearance
of 24" from the outdoor louver should
be maintained.

• For major obstructions such as a solid

fence, wall or other heat rejecting
device like a condensing unit, a mini-
mum distance of 72" should be kept.

12"

24"

60"

VPAK

VPAK

VPAK

POLE

FENCE

MAJOR OBSTRUCTION

BUILDING

OUTDOOR
CONDENSING

UNIT

72"

24"

SHRUB

VERT-I-PAK

®

units must be installed on an outside wall. Confi ned spaces and/or covered areas should be

avoided. Units should be installed no closer than 12" apart when two units are side by side. If three of more
units are to operate next to one another allow a minimum of 60" between units or pairs of units. Also, a vertical
clearance of 60" should be maintained between units. Units installed on the bottom fl oor should be mounted
at least 6" off of the ground.

A

B

60"

60"

60"

60"

LARGER RECESS OK. IF A> 5xB

12"

6"

60"

60"

60"

6"

60"

60"

6"

60"

60"

SMALL RECESS OK