Fujitsu Siemens Computers Tape Appliance User Manual
Page 4

Datasheet
⏐ Issue: January 2008⏐ CentricStor Virtual Tape Appliance
Page 4 / 3
Supported Operating Systems
System reliability
All rights reserved, including intellectual property rights. Technical data subject to modifications and
delivery subject to availability. Any liability that the data and illustrations are complete, actual or
correct is excluded.
Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which
by third parties for their own purposes may infringe the rights of such owner.
For further information see http://www.fujitsu-siemens.com/terms_of_use.html
Copyright © Fujitsu Siemens Computers 1/2008
Published by
Fujitsu Siemens Computers
Company stamp
Mainframes
BS2000/OSD
GCOS 8
z/OS (OS/390)
i5/OS (OS/400)
MSP
z/VM – z/VSE
VME (ICL)
XSP
Power
supply
redundancy
Component
redundancy
IUP, ICP, IDP, VLP
yes
yes
TVC yes
RAID 5
Internal SAN
yes
yes
Electrical per rack
Rated voltage
230 V
Open Systems
AIX
HP-UX
Reliant UNIX
Solaris
LINUX (SUSE, Red Hat)
Windows NT, 2000, 2003
Max. power draw (kVA)
3.6
Fuse protection (A)
16
CEE connector
Connection type
Environmental
NAS – NDMP Backup
NetApp Filer
EMC Celerra
Product class
B
Room supply air
double bottom supply air
yes
no
Temperature (°C)
15 to 35
Supported Backup Software with Open Systems
Rel. humidity (%)
20 to 80
Atempo TimeNavigator
CommVault
Galaxy Backup & Recovery
Computer Associates
BrightStor ARCserve
Standards compliance
Fujitsu Siemens Computers
NetWorker
Safety
EN 60950 / IEC 950
EMC NetWorker
DiskXtender UNIX/Linux
VDE 0805 UL 1950
CSA 22.2 No. 950
HP OpenView
OmniBack / Data Protector
IBM Tivoli
Storage
Manager
Radiation, RFI suppression
CE mark, FCC Class A *
(EN 55022B, EN 50082-1)
Syncsort Backup
Express
Operating noise (dB(A))
< 51
Symantec/Veritas Backup
Exec
NetBackup
Safety
EN 60950 / IEC 950
VDE 0805 UL 1950
CSA 22.2 No. 950
Supported Tape Libraries
Quantum / ADIC
Scalar 100
Scalar i500
Scalar 1000
Scalar i2000
Scalar 10K
AML/J, /E, /2
*
This product, together with the Fujitsu Siemens released accessory
components / -material, is in compliance with the objectives of emission
class A. In certain cases measures have to be taken to reduce the electro
magnetic influence to other equipment
Fujitsu LT130,
LT160,
LT270
Fujitsu Siemens Computers
Scalar 100
SL500
9084-221
3560
CentricStor solution platforms
IBM 3494,
3584
Following CentricStor systems are available with different
model configurations:
TS3500 on request
CentricStor VTA (Virtual Tape Appliance)
CentricStor VTC (Virtual Tape Controller)
CentricStor SBU (Smart Backup Unit)
Spectra Logic
T50, T120, T950
Sun StorageTek
L180, L700, L700E
L1400
L5500
SL500
SL8500
Powderhorn 9310
TimberWolf 9740
For special configurations ask your local Fujitsu Siemens
Computers representative.
Additional information is available at