Specifications, Electrical, Evaporator plumbing – Follett HCD1400R User Manual
Page 5: Ambient, Refrigeration, Weight ice production, Evaporator unit, Condenser unit, Separate circuit and equipment ground required, 3/8" liquid line 5/8" suction line

5
Specifications
Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical – 115/60/1
Maximum fuse – 15 amps
Amperage – 6 amps
Condenser unit
Standard electrical – 220V, 60Hz, 1 phase
Maximum fuse – 40 amps
Amperage – 21.4 amps
Evaporator plumbing
3/8" OD push-in water inlet
3/4" MPT
Notes: 3/4" vented drain line must slope a minimum of 1/4" per foot (6mm per 30.4cm run).
Drain to be hard piped and insulated.
Water shut-off recommended within 10 feet (3m).
Follett recommends installation of Follett water filter system (part# 00130286) in icemaker
inlet water line.
Ambient
Evaporator unit
Air temperature
100˚F/38˚C max.
50˚F/10˚C min.
Water temperature
90˚F/32˚C max.
45˚F/7˚C min.
Water pressure
70 psi max. (483 kPa)
10 psi min. (69 kPa)
Condenser unit
Air temperature
120˚F/49˚C max.
– 20˚F/-29˚C min.
Refrigeration
3/8" liquid line
5/8" suction line
Note:
Rack system installations require a reserve capacity of 10,000 BTU/hr at
0˚F (-18˚C) evaporator temperature.
Evaporator pressure regulator (not supplied) is required.
Weight
Ice
production
Evaporator unit
190 lbs (88kg)
Condenser unit
385 lbs (175kg)
F
C
50
10
60
16
70
21
80
27
90
32
60
16
1231
559
1182
537
1146
520
1110
504
1074
488
70
21
1206
548
1157
525
1121
509
1085
493
1049
476
80
27
1163
528
1127
512
1091
495
1055
479
1019
463
90
32
1128
512
1088
494
1048
476
1008
458
968
440
100
38
1098
499
1055
479
1012
460
969
440
926
421
lbs
kg
lbs
kg
lbs
kg
lbs
kg
lbs
kg
Inlet W
a
ter T
emper
atur
e F/C
Ambient Air Temperature F/C
Icemaker capacity/24 hrs.