Specifications

Input:
Voltage: 18-30 VAC
Output:
Maximum: 1 amp per terminal (3 amp total for all terminals)
Temperature Ranges:
Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
Differential range: 1°F to 3°F (0.5°C to 1.5°C) Accuracy: ± 1°F (± 0.5°C)
System configurations: Single stage heat pump
Terminations: R, C, W, Y, B, O, G
Note: This thermostat is designed for: Single stage electric

heating, heating/cooling systems and heat pump

systems. It will retain your setpoint temperatures in

memory for up to 30 minutes during a power outage.

SET
ROOM

DIFF

Temperature
differential setting

Room temperature

Room temperature
setpoint

Important Safety Information

• Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at the main

power source by unscrewing fuse or switching off circuit breaker

• Do not switch to “Cool” if outside temperature is below 50°F (10°C), this could damage your A/C system and cause

injury

• Do not install on voltages higher than 30 VAC
• All wiring must conform to local and national building and electrical codes and ordinances
• While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth with a mild

soap to wipe the outside of the thermostat cover