IMPORTANT:

This remote control

has been specially engineered to take
an air temperature sample every 5.5
minutes in the auto mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.

IMPORTANT:

The hand-held re-

mote control unit must be near the
heater. Do not keep the hand-held
remote control unit too close to the
heater. The thermostat on the hand-
held remote control unit will heat up
too quickly and turn the heater off.

OPERATING
HEATER

Continued

TEMP

STATUS

HI

LO

MAN

ON

AUTO

OFF

Increases Room
Temperature

Decreases Room
Temperature

Turns Burners
On and Off

Shows Current
Operation Mode

Shows Temperature Setting

Allows burners to be turned
on and off with the hand-
held remote unit.

Figure 24 - Thermostat Hand-Held Remote Control Unit Selections (FHRCT only)

The log heater will
automatically cycle between
pilot and the heat setting that
has been selected.

Figure 23 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for
Remote Operation

Selector Switch in Remote Position
(Optional Remote Control)

ON
OFF
REMOTE

O

FF

PILO

T

O

N

L O

I H

Control Knob in
On Position

Flame Adjustment Knob

Figure 25 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 26 - Incorrect Pilot Flame Pattern

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 25 shows a correct pilot flame pat-
tern. Figure 26 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not properly heating the thermocouple.
When the thermocouple cools, the heater
will shut down.

If pilot flame pattern is incorrect, as shown
in Figure 26

• turn heater off (see To Turn Off Gas to

Appliance, page 15)

• see Troubleshooting, pages 17 through 19

Pilot Burner

Thermocouple

INSPECTING
BURNERS

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the
holes in the fitting at the burner entrance.
These holes may become blocked with dust
or lint. Periodically inspect these holes for
any blockage and clean if needed. Blocked
air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes
with the heater running. All slotted burner
flame holes should be open with yellow
flame present. All round burner flame holes
should be open with a small blue flame
present. Some burner flame holes may be-
come blocked by debris or rust, with no flame
present. If so, turn off heater and let cool.
Either remove blockage or replace burner.
Blocked burner flame holes will create soot.

3.

Use the STATUS button on the hand-
held remote control unit to see the
operation mode being used and the
temperature setting selected. A red
light will come on beside the opera-
tion mode being used when the sta-
tus button is pressed.

4.

To turn the burners off when operat-
ing in the manual mode, press the OFF
button. If operating in the auto mode,
press the MAN button, then press the
OFF button. The pilot will remain lit.

IMPORTANT:

To turn the pilot off,

manually turn the control knob on the
heater to the OFF position.