CHAPTER 6: OPERATOR TROUBLESHOOTING
6-7
6.5 Troubleshooting Abnormal Burner Operation
PROBLEM
PROBABLE CAUSES
CORRECTIVE ACTION
Flame is visible
above flue opening
and burner is
excessively noisy.
A. Burner gas pressure is too high.
B. Gas valve vent tube clogged.
C. Gas valve regulator defective.
A. Call FASC to adjust pressure to
recommended standard.
B. Remove and clean vent tube and
reinstall.
C. Call FASC to replace gas valve.
Fryer is operating
normally, but flames
are rolling out of the
front of the burner.
Obstructed gas valve vent tube.
Shut the fryer down and clean the gas
valve vent tube in accordance the
instructions on Page 5-5 of this
manual.