Frymaster D User Manual
Page 10
DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-5
Interface Boards
(cont.)
IFB 106-6669 & 106-6710: These interface boards are used in Decathlon fryers with Frymaster
computer control systems.
INTERFACE BOARD P/N 106-6669
INTERFACE BOARD P/N 106-6710
FREQUENTLY USED TEST POINTS FOR INTERFACE BOARD P/N 806-4549 (previous style)
Test Meter
Setting
Pins
Test
Results
12VAC Power to Controller
50VAC Scale
1 and 3 on J3
12-18
24VAC Power to Right Module
50VAC Scale
8 on J3 and GROUND
22-28
24VAC Power to Left Module
50VAC Scale
8 on J1 and GROUND
22-28
12VDC Power to Right BL Relay
50VDC Scale
7 on J2 and 9 or 12 on J3
12-18
12VDC Power to Left BL Relay
50VDC Scale
9 on J2 and 9 or 12 on J1
12-18
24VAC Power to Right High-Limit
50VAC Scale
7 on J3 and GROUND
22-28
24VAC Power to Left High-Limit
50VAC Scale
7 on J1 and GROUND
22-28
120VAC Power*
250VAC Scale
11 on J3 and GROUND
110-125
120VAC Power To 120VAC Gas Valve* 250VAC Scale
10 on J3 and GROUND
110-125
Probe Resistance (Right)**
R x 1000 Ohms
2 on J3 and 4 on J3
***
Probe Resistance (Left)**
R x 1000 Ohms
2 on J1 and 4 on J1
***
* Where Applicable
** Disconnect 15-pin harness from controller before testing probe circuit.
*** See Probe Resistance Charts in this chapter.