beautypg.com

Owner’s manual, Installation, Continued – FMI FVF30PW User Manual

Page 9: Mantel clearances, Floor clearances, Determining minimum mantel clearance

background image

9

105194

OWNER’S MANUAL

Figure 7 - Minimum Mantel Clearances When Using Hood

INSTALLATION

Continued

Figure 6 - Minimum Mantel Clearances Without Using Hood

MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace opening and
mantel shelf. If you do not meet the clear-
ances listed below, you will need a hood.

Determining Minimum Mantel
Clearance

If you meet minimum clearance between
mantel shelf and top of fireplace opening, a
hood is not required (see Figure 6).

Determining Minimum Mantel
Clearance When using a Hood

If minimum clearances in Figure 6 are not
met, you must have a hood. When using a
hood there are still certain minimum mantel
clearances required. Follow minimum clear-
ances shown in Figure 7 when using hood.

NOTICE: Surface temperatures of
adjacent walls and mantels be-
come hot during operation. Walls
and mantels above the firebox
may become hot to the touch. If
installed properly, these tempera-
tures meet the requirement of the
national product standard. Fol-
low all minimum clearances
shown in this manual.

NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the
following:
• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level,

you must maintain the minimum dis-
tance of 14" to combustibles (see Fig-
ure 8).

B. If combustible materials are less than

14" to the fireplace, you must install
appliance at least 5" above the combus-
tible flooring (see Figure 9).

Minimum Non-
Combustible
Material

Minimum Non-
Combustible
Material Height

Distances to
Underside of
Mantel

Top of Fireplace
Opening

Underside of
Mantel Shelf

Mantel Shelf

12"

8"

(A)

18"

8"

20"

14"

22"

17"

24"

20"

All minimum
distances are
in inches

Log Set
24"/30" Models

18" Model

2

1

/2

"

6"

8"

10"

Minimum Non-
Combustible
Material

8"
Min.

12"

15"

18"

All minimum
distances are
in inches

20"

2

1

/2

"

6"

8"

10"

12"

Distances to
Underside of
Mantel

Hood

Top of Fireplace
Opening

Log Sets
All Models

Underside of
Mantel Shelf

Mantel Shelf

Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring

14"
Min.

Combustible
Material

Noncombustible Material

Hearth

5"
Min.

Combustible
Material

Hearth

Combustible
Material

5”
Min.

Continued

(HDABK, HDABR)

This manual is related to the following products: