beautypg.com

Specifications, Electrical, Plumbing – Follett VU155K User Manual

Page 5

background image

Specifications

Electrical

Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each.

Model

Icemaker

Dispenser

number

amperage

amperage

VU155K series

11.0 amps ea

8.7 amps

Plumbing

Dispenser

3/4" PVC pipe nipple for bin drain

3/4" PVC pipe nipple for drain pan drain

1" ID hose for beverage bath drain

Beverage connections

1/4" ID syrup beverage hose

3/8" 45° flair fitting for water inlet

1/4" ID CO

2

3/8" ID plain water inlet

Note: Set CO

2

pressure to 75 psi and syrup pressure to 60 psi.

Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.

Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.

Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.

Icemaker

Refer to detailed specifications in icemaker installation manual packed with icemaker

5