Specifications
Electrical
Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each.
Model
Icemaker
Dispenser
number
amperage
amperage
VU155K series
11.0 amps ea
8.7 amps
Plumbing
Dispenser
3/4" PVC pipe nipple for bin drain
3/4" PVC pipe nipple for drain pan drain
1" ID hose for beverage bath drain
Beverage connections
1/4" ID syrup beverage hose
3/8" 45° flair fitting for water inlet
1/4" ID CO
2
3/8" ID plain water inlet
Note: Set CO
2
pressure to 75 psi and syrup pressure to 60 psi.
Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.
Icemaker
Refer to detailed specifications in icemaker installation manual packed with icemaker
5