3
Installation instructions
Height of rangehood
Please read the entire instructions BEFORE installing the rangehood.
Ascertain the desired installation height of the rangehood.
When installing the rangehood, the lower edge of the unit
must be a minimum of 600 mm (650 mm for gas cooker)
above the cooking surface.
The recommended position for the hood is 650 mm above
the hotplates.
Any installation above 750 mm will compromise the
extraction performance.
A = 600 min (electric cook top)
A = 650 min (gas cook top)
Ducting options
Some authorities require rangehoods to be vented outside. Attention should be given to ensure
that any applicable regulations concerning the discharge of exhaust air is fulfilled.
285 x 85 mm rectangular, or 150 mm diameter round ducting (using a rectangular-to-round
adaptor) can be used in conjunction with this model.
For optimal efficiency, use smooth ducting for reduced noise and increased airflow. Flexible
ducting should only be used as a last resort.
Note: we recommend an Easy Fit by Fisher & Paykel or a UNIDUCT ducting system, products that
have been designed to expel air efficiently.
Fig.2 Positioning
Not less than 650 mm
Gas Burner
Fig.3 Ducting options
Top ducting through roof
Rear ducted
Side ducting