beautypg.com

Product specifications – Fedders FV80 Series User Manual

Page 2

background image

Product Specifications

2

Specifications subject to change without notice.

NOTES:

1. Values based on Natural Gas usage

2. Important: It is required to size fuses and wires properly and make electrical connections

in accordance with the National Electrical Code and/or all existing local codes

PRODUCT SPECIFICATIONS

Model Number

FV80A070-4A

FV80A085-4A

FV80A115-5A

PERFORMANCE RATINGS

Input - High Fire (Btu) - Second Stage

1

68,000

85,000

115,000

Output - High Fire (Btu)

1

54,400

68,000

92,000

Input - Low fire (Btu) - First Stage

1

47,600

59,500

80,500

Output - Low fire (Btu)

1

38,080

47,600

64,400

AFUE

80%

80%

80%

High

30-60

30-60

30-60

Low

25-45

30-50

25-45

Position

All position

All position

All position

Gas Connection

1/2" NPT

1/2" NPT

1/2" NPT

NO

X

(Ng/J)

<40

<40

<40

ELECTRICAL DATA

Volts, Phase, Herz

115 / 60 / 1

115 / 60 / 1

115 / 60 / 1

Min. / Max. Voltage

102 / 132

102 / 132

102 / 132

Transformer (V.A.)

40

40

40

Min. Time Delay Breaker or Fuse

2

15 AMP

15 AMP

15 AMP

HEAT EXCHANGER

Number of Tubes

4

5

7

Approximate BTUs / Tube

17,000

17,000

17,000

Tube Diameter (inches)

1.5

1.5

1.5

Number of Passes

4

4

4

BLOWER PERFORMANCE DATA

A/C Cooling Max. (CFM) @.5 static

1,350

1,550

1,750

Blower Wheel

10 x 8

10 x 10

11 x 10

A/C Cooling Tons @ .5 esp

1.5 - 3.5

2 - 4

2.5 - 5

Motor Speed

Variable

Variable

Variable

CABINET DIMENSIONS

Cabinet Width (inches)

17 1/2

20 1/2

22

Cabinet Height (inches)

35

35

35

Cabinet Depth (inches)

28 1/4

28 1/4

28 1/4

Volume (Cubic Feet)

10.28

12.05

12.93

PACKAGING DIMENSIONS

Package Width (inches)

21 1/4

24 1/4

25 3/4

Package Height (inches)

37 3/4

37 3/4

37 3/4

Package Depth (inches)

31 3/4

31 3/4

31 3/4

Loadability 40’ High Cube Container

116

104

100

Packaged Weight (lbs)

132

146

163

Temp. Rise