Clogged pilot orifice, Loose/corroded wire connections, Low or no voltage out of thermopile – Frymaster 35 Series User Manual
Page 16
1-12
6. Basket Lift malfunctions.
The probable causes of each category are discussed in the following sections. A series of
Troubleshooting Guides is included at the end of the chapter to assist in identifying some of the
more common problems.
1.9.1 Pilot Failures
There are two categories: no pilot flame and unreliable flame.
No pilot flame
1. No gas or insufficient gas supply
2. Clogged pilot orifice
3. Air in gas lines ( usually in new installations)
Unreliable flame
1. Open or grounded high limit
2. Loose/corroded wire connections
3. Low or no voltage out of thermopile
4. Bad gas valve
1.9.2 Problems Related to the Gas and/or Electrical Current