background image

shallow and deep limits and a depth below

keel offset feature. These settings once made

are stored in memory and will remain even if

the battery is disconnected.
Operation:

1. Power on. The depth sounder will activate

automatically when the power to it is initially

turned on. You do not have to press any key.

The LCD will illuminate showing the depth

in the upper display. The lower display will

show a “W” and water temperature.
Press the “Up” switch and the lower display

will change to an “A” and the air temperature

will be displayed.
Press the “Down” switch to return to the

water temperature display.To turn the depth

sounder off, press and hold the “Mode”

switch for 4 seconds. Pressing the “Mode”

switch again will reactivate the unit.
NOTE: The instrument is designed to have

the internal LED lighting remain on as long

as power is supplied even if the unit is turned

“off” by the “Mode” switch.
2. Depth alarm.

Deep mode: Pressing the “Mode” switch

again displays the “DEEP”, deep depth alarm

setting. This is the deepest water that will

activate the alarm. Press and hold the “Up”

or the “Down” switch to adjust the reading to

the desired depth.
Shallow mode: Press the “Mode” switch to

display the “SHAL”, shallow depth alarm

setting. This is the shallowest water that will

activate the alarm. Press and hold the “Up”

or the “Down” switch to adjust the reading

to the desired depth.
When the depth of the water is less than

the shallow depth alarm setting the audible

alarm will sound rapidly. When the depth

of the water is deeper than the deep depth

alarm setting the audible alarm will sound at

2 beeps per second.
NOTE: To fully deactivate an alarm, reset it to

zero. Pressing the “Mode” switch temporarily

deactivates the alarm. To reactivate the alarm

press the “Mode” switch until the depth

reading appears.
3. Keel offset. Pressing the “Mode” switch

again displays the “KEEL,” keel offset

setting. This can be set so that the depth

sounder either shows the depth below the

keel or the depth below the transducer.
Press the up or down arrow switches to adjust

the reading to the desired depth no more than

19.9 ft.
For example if the bottom of the keel is 2.5

feet below the transducer and you want the

depth sounder to read the depth below the

keel, the display should be adjusted to read

2.5 FT.
NOTE: Once a keel offset is programmed,

the shallow and deep alarms will be activated

by the depth below the keel.
Units:

Change the unit of measure. The lower

display will show “UNIT” and the upper

display will show either “US” or “EURO”

for metric units. Pressing the up or down

switches will cycle through the choices.
Pressing the “Mode” switch will save the

units shown in the display and change the

display
Back to the normal depth mode. There will

be no units shown in the displays. It will be

up to the operator to determine the units from

the temperature reading.