Specifications – Fluke 566 User Manual
Page 28

566/568
Users Manual
20
Specifications
Feature 566
568
IR Temperature Range
-40
°
C to 650
°
C
(-40
°
F to 1200
°
F)
-40
°
C to 800
°
C
(-40
°
F to 1470
°
F)
Accuracy
<0 °C: ±(1.0 °C + 0.1 °/1 °C)
>0 °C: ±1 % or ± 1.0 °C, whichever is greater
(<32 F±2 °F ±0.1 °/1 °F)
>32 °F: ±1 % or ±2 °F), whichever is greater
Repeatability
±
0.5 % of reading or
±
0.5 °C (1 °F), whichever is greater.
Display Resolution
0.1
°
C / 0.1
°
F
Spectral Response
8 to 14
μ
m
Response Time (95%)
<500 ms
K-Type Thermocouple Input
Temperature Range
-270
°
C to 1372
°
C (-454
°
F to 2501
°
F)
K-Type Thermocouple Input
Accuracy
-270
°
C to -40
°
C:
±
(1 °C + 0.2 °/1 °C)
(-454
°
F to -40
°
F:
±
(2 °F + 0.2 °/1 °F))
-40
°
C to 1372
°
C:
±
1 % or 1 °C (-40
°
F to 2501
°
F:
±
1 % or 2 °F),
whichever is greater
K-Type Thermocouple
Resolution
0.1
°
C/0.1
°
F
Distance:Spot
(90% energy)
30:1 50:1
Laser sighting
single laser, output <1 mW Class II, wavelength
630 to 670 nm
Minimum spot size
19 mm
Emissivity
Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of
common materials
Data storage
20 points
99 points
Communication
none USB
2.0
Operating Altitude
3000 meters above mean sea level
Storage Altitude
12,000 meters above mean sea level
Relative Humidity
10 % to 90 % RH non-condensing up to 30 °C (86 °F)
Operating Temperature
0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature
-20 °C to 60 °C (-4 °F to 140 °F)
Vibration
2.5 G, IEC 68-2-6
Weight
0.322 kg (0.7099 lb)
Dimensions
17.69 cm (6.965 in) H x 16.36 cm (6.441 in) L x 5.18 cm (2.039 in) W
Power
2 AA /LR6 Batteries
2 AA /LR6 Batteries
or USB connection when used
with a PC