beautypg.com

Continuous events, Alarms, Snmp trap – Finisar Brocade Fabric Watch User Manual

Page 21: Error log entry, Locking the port log

background image

Fabric Watch User’s Guide

3-9

Using Fabric Watch

3

Continuous Events

A continuous event results in an event at each time interval from when the boundary is initially
exceeded until the threshold value has returned within the boundaries. For example, if port
utilization is above the upper boundary, a new event is generated at each behavior interval until
utilization falls below the upper boundary. The following events can be generated as continuous
events:

Started

No alarm is generated.

Below

Counter is below the lower boundary.

Above

Counter is above the upper boundary.

Exceeded

Counter is below the lower boundary or above the upper boundary.
Accompanies a below or above event.

Changed

Counter value has changed.

Alarms

Each event can generate one or more alarms. Fabric Watch supports the following types of alarms:

SNMP trap

Switch event log entry

Locking of the port log

RAN

Email

SNMP Trap

The following information is forwarded to an SNMP management station:

Name of the element

Class, area, and index of the threshold

Type of event generated

Element value

New state of element

Error Log Entry

The internal error log maintains a record of the event, up to a maximum of 64 entries. If configured
to do so, error log entries are forwarded to the SYSLOGD facility.

Locking the Port Log

Locking the Port Log freezes the switch port log to retain detail information about a problem. It is
typically used in conjunction with the error log entry.