Frymaster BK1814E User Manual
Page 12
2-3
2.2 Power
Requirements
Three (3) Phase Requirements
MODEL VOLTAGE
WIRE
SERVICE
MINIMUM WIRE
SIZE
AWG (mm)
AMPS
(per leg)
RE14/RE1814
208 3 6
(4.11)
39
RE14/RE1814
240 3 6
(4.11)
34
RE14/RE1814
480 3 8
(2.59)
17
RE14/RE1814
220/380
4 6
(4.11)
21
RE14/RE1814
240/415
4 6
(4.11)
20
RE14/RE1814
230/400
4 6
(4.11)
21
RE17/RE1814E 208
3
6 (4.11) 48
RE17/RE1814E
240 3 6
(4.11)
41
RE17/RE1814E
480 3 6
(4.11)
21
RE17/RE1814E
220/380
4 6
(4.11)
26
RE17/RE1814E
240/415
4 6
(4.11)
24
RE17/RE1814E
230/400
4 6
(4.11)
25
RE22/RE1822
208 3 4
(5.19)
61
RE22/RE1822
240 3 4
(5.19)
53
RE22/RE1822
480 3 6
(4.11)
27
RE22/RE1822
220/380
4 6
(4.11)
34
RE22/RE1822
240/415
4 6
(4.11)
31
RE22/RE1822
230/400
4 6
(4.11)
32
Single Phase Requirements
MODEL VOLTAGE
WIRE
SERVICE
MINIMUM WIRE
SIZE
AWG (mm)
AMPS
(per leg)
RE14/RE1814
208 2 3
(5.83)
68
RE14/RE1814
240 2 4
(5.19)
59
RE14/RE1814
480 2 8
(3.26)
30
NOTICE
If this appliance is permanently connected to fixed wiring, it must be connected by
means of copper wires having a temperature rating of not less than 167°F (75°C).
DANGER
This appliance must be connected to a power supply having the same voltage and
phase as specified on the rating plate located on the inside of the appliance door.
DANGER
All wiring connections for this appliance must be made in accordance with the
wiring diagram(s) furnished with the appliance. Refer to the wiring diagram(s)
affixed to the inside of the appliance door when installing or servicing this
equipment.
2.3
Positioning the Fryer
DANGER
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster Service Hotline
at 1-800-551-8633.