Operation – FMI COMFORT FLAME CGCFTNA User Manual
Page 20

www.fmiproducts.com
124978-01B
20
Note: If pilot does not stay lit, refer to
Troubleshooting, page 24. Also contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7. This fireplace has a safety
interlock system. Wait one (1) minute
before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
9. To shut off burner only and leave pilot lit,
turn countrol knob clockwise
to
PILOT position.
oPeRATIoN
Continued
Ignitor Button
Figure 28 - Control Knob In The OFF
Position
Control Knob
Thermocouple
Pilot Burner
Figure 29 - Pilot (Propane/LP Shown)
Ignitor Electrode
LIGHTING
INSTRUCTIONS
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
1. STOP! Read the safety information start-
ing, page 19.
2. Make sure equipment shutoff valve is
fully open.
3. Turn control knob clockwise
to OFF
position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in safety information, page 19. If you don’t
smell gas, go to next step.
5. Turn control knob counterclockwise
to PILOT position. Press in control knob for
five (5) seconds (see Figure 28).
Note: You may be running this fireplace
for the first time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
• If control knob does not pop up when
released, contact a qualified service
person or gas supplier for repairs.
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. Pilot is attached to front of burner. If
needed, keep pressing ignitor button until
pilot lights.