How to install the unit, Window requirements, Hs il g ne – Friedrich CP10 User Manual

Page 11

background image

10

27" to 39"

Offset

1

/

2

" to 1

1

/

4

"

Sill

Exterior

Interior wall

23

5

/

8

" min.

(Without frame curtain)

Stool

16" min

(With frame curtain)

About

1

/

2

"

30"~60"

Awning

Cooled air

Fence

Over 20"

Heat

radiation

How to Install the Unit

1. To prevent vibration and excess noise,

make sure the unit is installed securely

and firmly

2. Install the unit where the sunlight does not

shine directly on the unit.

3. The outside of the cabinet must extend outward

for at least 12" and there shouldbe no obstacles,

such as a fence or wall,within 20" from the back

of the cabinet, as it will prevent heat radiation

of the condenser.

Restriction of outside air will greatly reduce

the cooling efficiency of the air conditioner.

4. Install the unit with a rear, downward slope, so the back is slightly lower than the front

(about 1/4" bubble on a level). This will force condensation to flow to the outside.

5. Install the unit with the bottom about 30" 60" above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

• This unit is designed for installation in standard

double hung windows with actual opening widths

from 27" to 39".

• The top and bottom window sash must open

sufficiently to allow a clear vertical opening of 16"

from the bottom of the upper sash to the window

stool.

CAUTION: DO NOT cover or block any of the side louvers. All side louvers of the cabinet must remain

exposed and unobstructed to the outside of the structure.

-