beautypg.com

Caution, Faceplate backplate replacing the fuse, Specifications – First Act MA120 User Manual

Page 2

background image

1. INPUT JACK

Connect instrument cable here (1/4” jack).

2. MASTER

Controls the total output level of amplifier.

CHANNEL 1 – CLEAN CHANNEL

3. LEVEL

Controls the output level.

4. TREBLE

Adjusts high frequency output.

5. BASS

Adjusts low frequency output.

6. CHANNEL SWITCH

Switch off/out for Channel 1–indicated

by green LED.

Switch on/in for Channel 2–indicated

by red LED.

7. LED

Indicates amplifier power on/off.

CHANNEL 2 – DISTORTION CHANNEL

8. LEVEL

Controls the output level.

9. GAIN

Controls the input level. Increasing gain

adds distortion, or overdriven rock tone;

decreasing gain produces a cleaner sound.

10. TREBLE

Adjusts high frequency output.

11. MIDDLE

Adjusts middle frequency output.

12. BASS

Adjusts low frequency output.

13. POWER ADAPTOR/ FUSE COMPARTMENT

Connection for power cable. Use only the

power cable supplied with this amplifier.

14. POWER

On/off switch.

15. AUDIO IN

Input jack for external audio device such as

CD or MP3 player (device should have its

own volume control).

16. PHONES

Connects to stereo headphones, which

cancels speaker output.

1

4

6

3

2

14

13

FACEPLATE

BACKPLATE

REPLACING THE FUSE

An additional fuse has been enclosed in the fuse

compartment of your amplifier, directly below

the power input. The fuse compartment contains

an active fuse and a replacement. The fuse protects

against power surges. If your amplifier does not

power up as usual, the fuse may need to

be replaced.

If the fuse fails:

1. Turn the amplifier power off.

2. Unplug the amplifier.

3. Detach the power cord and set aside.

4. Carefully insert a flathead screwdriver to

open the fuse compartment. Be careful not

to break the fuse inside.

5. Remove the blown fuse from the inner

(active) slot.

6. Move the new fuse from the outer slot to the

inner slot.

7. Close the fuse compartment.

8. Discard the blown fuse.

Note: If you replace the fuse and the amplifier

still does not power up, have the unit checked by

a qualified repair technician.

Open the fuse compartment.

Remove the blown fuse from the inner (active)
slot. Move the new fuse from the outer slot to
the inner slot.

USING ANOTHER TYPE IS A POTENTIAL FIRE HAZARD.

CAUTION

REPLACE ONLY WITH SAME
TYPE 250V, 1A FUSE

.

ACTIVE FUSE

REPLACEMENT FUSE

SPECIFICATIONS

Output Power:

20 watts RMS

Frequency Range:

40 Hz ~ 8 kHz

Speaker:

8" / 25W / 4 ohms

Input Sensitivity:

26 mV

Power Supply:

Detachable,

UL-approved

power cable

Dimensions: (LxWxH)

12.5" x 13" x 6.75"

Weight:

15 lbs.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

5

8

9

10

11

12

7

15

16

CHANNEL 1

CHANNEL 2