Warning, Maintenance / service – Friedrich P012A User Manual
Page 16

MAINTENANCE / SERVICE
Unplug and/or disconnect all electrical power
to the unit before performing inspections,
maintenances or service.
Failure to do so could result in electric shock,
serious injury or death.
WARNING
RISK OF ELECTRIC SHOCK
Preparation for storage
1. Turn off the air conditioner, disconnect the power.
2. Perform proper maintenance to the air filter and other
parts.
3. Open the base stopper to drain out all of the water from
the base. Operating the unit in fan only mode for 12 hours
will help ensure there is no moisture within the unit.
4. Cover the unit to prevent dust or filth from entering the unit.
Cleaning the air filter
If the air filter is blocked with a lot of dust, the air flow volume
will be reduced. Clean the filter once every two weeks.
Open and clean the air filter:
1. Pull the filter out as shown in the drawing.
2. Take out the air filter from the filter cover.
3. Wash the air filter by immersing it gently into warm (about
40°C or 104°F) water with a neutral detergent or vacuum
the filter clean.
4. Rinse the filter and dry it thoroughly in a shaded place.
5. Install the air filter back to its original place.
Cleaning the air conditioner
Clean the surface of the unit with a damp cloth, then dry us-
ing a duster or similar.
Do not use chemical solvent (like benzene or alcohol) to
clean the surface of the unit. If you do so, the surface may
be scratched, damaged or even cause the case to become
deformed.
Prior to operating seasons
1. Check to ensure that the air inlets and outlets of the unit
are not blocked.
2. Make sure that air filter is properly in place before operat-
ing the machine. If the machine is operated with air filter
removed, dust and foreign objects will result in faulty per-
formance of the air conditioner.
Drain valve
14
- P012B WallMaster Series 12000 BTU Thru-the-Wall Smart Air Conditioner Warranty WallMaster Series 11600 BTU Thru-the-Wall Smart Air Conditioner Warranty WallMaster Series 8000 BTU Smart Thru-The-Wall Air Conditioner Warranty KS15 EM24 ES16 EM18 EL36 ZQ07 ZQ05 CP12 Chill Premier Series Slide-Out Chassis Smart Room Air Conditioner Warranty Kuhl Series 28000 BTU Window Air Conditioner Warranty Chill Premier Series Slide Out Chassis Smart Window Air Conditioner Warranty Chill Premier Series Smart Window Air Conditioner Warranty ZoneAire Series 11,000 BTU Smart Portable Air Conditioner Warranty ZoneAire Series Single Hose Smart Portable Air Conditioner Warranty ZoneAire Series 12,000 BTU Dual Hose Smart Portable Air Conditioner Warranty CP06 ZStar D30C D40C D65C CP08 ZQ10 ZQ08 CP18C30 Kuhl Series 23,000 BTU Smart Window Wall Room Air Conditioner Warranty Kuhl Series 12000 BTU Smart Window Air Conditioner Warranty