beautypg.com

Warning – Firex COZ-1 User Manual

Page 2

background image

Normal Operation

When no carbon monoxide is present, the red light will flash approximately
once every 60 seconds.

Test / Reset Button (in Normal operation)
If required, the alarm operation can be checked for correct operation
by pushing the Test/Reset button on the front of the unit.

Alarm Conditions
When the unit detects carbon monoxide the alarm signal is sounded
continuously. The red alarm light will flash and the alarm will sound
approximately 4 times every 5 seconds.

When the unit has been in alarm for a period of approximately 4 minutes,
the alarm signal will be given every 60 seconds.

Test / Reset Button (in Alarm condition)
If required, the audible alarm signal can be silenced for a period of 6 minutes by
pushing the Test/Reset button on the front of the unit. The red light will continue
to flash.

If the carbon monoxide is still present after the 6 minute period, the audible
alarm will resume the previous alarm condition. The Test/Reset button should
not be used repeatedly and the actions “What to do when the alarm sounds”
should be followed.

Return to Normal Operation
When the carbon monoxide gas disperses, the alarm will stop. The red light will
flash approximately once every 60 seconds (normal operation). The user should
check for the source of CO any time the alarm has sounded, even if the alarm
has returned to its normal working conditions.

Battery Replacement / Fault Warning
When the batteries need replacing the unit will sound 1 short beep once every
60 seconds. The batteries must then be replaced. The red light will flash once as
normal. If the detector continues to sound 1 short beep every 60 seconds it must
be replaced.

Room spaces should be well ventilated when household cleaning supplies
are used as these may cause a false alarm.

The alarm is designed to be wall mounted using the hardware provided.
Find a position to install the alarm (see “Where to put the alarm” and
“Where not to put the alarm”).

Option 1
Special Mounting Pad with Nail (supplied)
Place the nail through the mounting pad.
Using a hammer, gently knock the nail into
the wall ensuring that the mounting pad is
not hammered too firmly into the wall.

Option 2
Screw and Insert (NOT supplied)
If the wall is too hard to use the nail,
use a No. 4 round head screw and insert.

Press the test/reset button on the front of the alarm, hold for several
seconds and check that the red light flashes and the audible alarm sounds.
The detector can be hung on the protruding nail using the ‘keyhole’ on
the back.

Model:

COZ-1

Gas Detected:

Carbon monoxide

Detection Principle:

Electro-chemical cell

Alarm Indication:

Audible and visual alarm

Alarm Levels:

70ppm

Between 60 and 240 minutes

150ppm

Between 10 and 50 minutes

400ppm

Between 4 and 15 minutes

Operating Temperature:

40°F to +100°F

Humidity Range:

15 to 95% RH

Warm-up time after initial switch on: Instantaneous
Dimensions:

4.69” x 3.14” x 1.50”

Weight:

6oz.

WARNING

Activation of your CO alarm’s audible buzzer

indicates the presence of carbon monoxide (CO)

which can KILL YOU.

1. Operate reset/silence button.

2. Call your emergency service

(Phone: _______________________________) [fire department or 911].

3. Immediately move to fresh air – outdoors or by an open door/window.

Do a head count to check that all persons are accounted for. Do not
re-enter the premises nor move away from the open door/window until
the emergency services have arrived, the premises have been aired out
and your alarm remains in its normal condition.

4. After following steps 1-3, if your alarm reactivates within a 24-hour

period, repeat steps 1-3 and call a qualified technician
(Phone: _______________________________) to investigate for sources
of CO from fuel burning equipment and appliances and inspect for proper
operation of this equipment. If problems are identified during this
inspection have the equipment serviced immediately. Note any
combustion equipment not inspected by the technician and consult the
manufacturers’ instructions, or contact the manufacturers directly, for
more information about CO safety and this equipment. Make sure that
motor vehicles are not and have not been operating in an attached
garage or adjacent to the residence.

Please add the telephone number of your emergency services and a qualified
technician to the labels provided and place one copy next to the appliance and
the other near a source of fresh air where you plan to gather in the event of
an alarm.

Pull down catch to open detector and pull ribbon to remove batteries.

Carefully remove old batteries from battery housing and dispose
of old batteries with care.

Using only batteries listed in 'Care and Maintenance of Alarm' insert 3 new
batteries, ensuring they snap securely into place and cannot be shaken
loose. When inserting the batteries, ensure the polarity is correct - ie:
positive end of battery (+) aligns with the (+) symbol in the battery housing.
Press the test/reset button and check that the red light flashes and the
buzzer sounds. The detector is now operating and ready for use.

NOTE:
WITH THE BATTERIES REMOVED IT WILL NOT BE POSSIBLE
TO CLOSE THE ALARM LID.

Dispose of the alarm in accordance with local regulations.

WARNING: DO NOT DISPOSE OF IN FIRE.

Should you experience difficulty in obtaining a replacement alarm contact:

mounting pad

nail

insert

screw

wall

5mm

wall

WALL MOUNTING INSTALLATION

WHAT TO DO WHEN THE ALARM SOUNDS

SELF - ADHESIVE LABELS

TO REPLACE BATTERIES

DISPOSAL

SPECIFICATION

OPERATION OF THE ALARM

WARRANTY INFORMATION

Your COZ-1 Carbon Monoxide Alarm (excluding batteries) is warranted for 5
years from date of purchase against defect in materials and workmanship
under normal use.

The manufacturers liability is limited to the repair or replacement of any part of
the alarm which is found to be defective in materials or workmanship under
normal use during the applicable period from date of purchase. The
replacement product will be in warranty for the remainder of the original
warranty period or for six months, whichever is longer.

The warranty is void if the product has been damaged by accident,
unreasonable use, neglect, tampering or other causes not arising from defects
in materials or workmanship.

The manufacturer makes no warranty, expressed or implied, written or oral,
including that of merchantability or fitness for any particular purpose, with
respect to the batteries.

The manufacturer makes no other express warranty for this alarm. No agent
representative, dealer or employee of the manufacturer has the authority to
increase or alter the obligations or limitations of this warranty.

In no case shall the manufacturer be liable for any consequential or incidental
damages for breach of this or any other warranty, expressed or implied
whatsoever, even if the loss or damage is caused by the company’s negligence
or fault. The manufacturer shall have no liability for any personal injury,
property damage or any special, incidental, contingent or consequential
damage of any kind resulting from gas leakage, fire or explosion.

Some states do not allow limitation on how long an implied warranty lasts
and/or do not allow the exclusion or limitation of accidental or consequential
damages so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights
which may vary from state to state.

Any products in need of repair should be returned to:

In the U.S.:

In Canada:

Climate Controls Americas

Climate Controls Canada, Inc.

28C Leigh Fisher Blvd

3505 Laird Road - Unit #14

El Paso, TX 79906

Mississauga, Ontario L5L 5Y7

Please include a note clearly describing the problem

when you return the alarm.

The alarm is not fitted with an on/off switch, it is automatically switched on when the tab is removed. This is to ensure that the alarm cannot be inadvertently
switched off and therefore fail to detect a build-up of carbon monoxide.

4 beeps

Red Light

Buzzer

4 flashes

1 every 60 secs

4 beeps

4 flashes

4 every 5 secs

First
sequence:

Second
sequence:

4 beeps every 5 secs

4 every 60 secs

4 beeps every 60 secs

4 every 5 secs

no beep for 6 minutes

4 every 60 secs

4 beeps every 60 secs

1 beep every 60 secs

1 every 60 secs

1 every 60 secs

If problems with this alarm cannot be resolved, contact:

Technical Support: (800) 445-8299

Monday–Friday 7:30AM–5:30PM CST