beautypg.com

Electrical parts – Friedrich CP10F10 User Manual

Page 11

background image

Service Manual 11

Electrical Parts

1. Remove the cabinet.
2. Remove the evaporator.
3. Remove the orifice.
4. Remove the blower.
5. Remove the fan.
6. Remove the control box cover and housing of the

motor in the control box.

7. Remove the 2 screws which fasten the motor from

the mount motor. (See Figure 7)

8. Remove the motor.
9. Re-install the components by referring to the

removal procedure, above.(See Figure 7)

Figure 7

3. MOTOR

1. OVERLOAD PROTECTOR

1. Remove the cabinet.
2. Remove the nut which fastens the terminal cover.
3. Remove the terminal cover. (See Figure 8)
4. Remove all the leads from the overload protector.
5. Remove the overload protector.
6. Re-install the component by referring to the

removal procedure, above.

Figure 8

Disassembly

2. COMPRESSOR

1. Remove the cabinet.
2. Discharge the refrigerant system using a Freon

TM

Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon

TM

. Leave the valve in place after

servicing the system.

3. Remove the overload protector.
4. After purging the unit completely, unbraze the

suction and discharge tubes at the compressor
connections.

5. Remove the 3 nuts and the 3 washers which

fasten the compressor.

6. Remove the compressor. (See Figure 9)
7. Re-install the components by referring to the

removal procedure, above.

Figure 9