beautypg.com

8 restraining the fryer – Frymaster COOL ZONE SERIES *8196329* User Manual

Page 12

background image

YSCFHC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS

CHAPTER 2: IMPORTANT INFORMATION

2-5

2.8 Restraining the Fryer

DANGER

No structural material on the fryer should be altered or removed to accommodate

placement of the fryer under a hood. Questions? Call the Frymaster Dean Service

Hotline at 1-800-551-8633.

1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the

top of the frypot to verify that the unit is level, both side-to-side and front-to-back.

• To level fryers equipped with legs, the bottom of the legs can be screwed out up to one inch for

leveling. Legs should also be adjusted so that the fryer(s) are at the proper height in the frying
station.

• For fryers equipped with casters, there are no built-in leveling devices. The floor where the

fryers are installed must be level.


2. With the fryer level in its final position, install the restraints provided with the unit to limit its

movement so that it does not depend on or transmit stress to the electrical conduits/connections
or the gas supply line. Install the restraints in accordance with the provided instructions (see
illustration below). If disconnected for service or other reasons, the restraints must be
reconnected before the fryer is used.

DANGER

Adequate means must be provided to limit the movement of this appliance without
depending on or transmitting stress to the electrical conduit. A restraint kit is
provided with the fryer. If the restraint kit is missing contact your local Frymaster
Factory Authorized Service Center (FASC) for part number 826-0900.

NOTE: If you need to relocate a fryer installed with legs, remove all weight from each leg
before moving. If a leg is damaged, contact your service agent for immediate repair or
replacement.