Safety label – FireplaceXtrordinair 36 DV EFIII User Manual
Page 41
Safety Label
4 1
Travis Industries
4040708
1 0 0 - 0 1 1 6 0
The safety (listing) label is adhered to the base of the fireplace near the gas control valve. A copy of
the safety label is shown below.
Fireplace Xtrordinair 36 DV XL
Direct V
ent
Vented Gas Fireplace Heater
Tested and certified by OMNI-T
est Laboratories, Inc. to the combustion performance and construction requirements of
ANSI
Z21.88a-2000 and applicable sections of UL
307b.
This appliance must be installed in accordance with local codes, if any; if none, follow National Fuel Gas Code
ANSI Z223.1.
Installation in Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety Standard, T
itle 24
CFR, Part 3280.
This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner
’s
manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used.
Vented Gas Fireplace Heater
. Not for use with Solid Fuel.
The 36 DV XL
is designed to operate on natural gas, or propane (LPG).
THIS
APPLIANCE IS F
ACT
OR
Y
SET FOR USE WITH
NA
TURAL
GAS.
For conversion to Propane (LPG) use factory supplied kit. See owner
’s
manual for information on making these changes.
W
ARNINGS:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the informa
tion
in the owner
’s
and installation manual provided with this appliance. For assistance or additional information consult a qualifi
ed
installer
, service agency or the gas supplier
.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
This vented gas fireplace heater is not for use with air filters.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other
liquids having flammable vapors away
.
CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel should be done by a
licensed or qualified service person.
Only use direct vent systems listed in owner
’s
manual to vent this appliance to the exterior (direct discharge only without duc
t
connection).
This appliance must be properly connected to a vanting system in accordance with manufacturer
’s installation instructions.
W
ARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in
carbon monoxide (CO) poisoning and possible death.
10850 1
17th Pl. N.E. Kirkland, W
A
98033
FAN TYPE VENTED CIRCULA
T
O
R
Blower Electrical Rating: 1
15 V
., 1.5
Amps, 60 Hz, 150 watts
L.P
.
N.G.
L.P
.
N.G.
Input Rate on “HI” (BTU/Hr)
.........
43,000
43,000
Minimum Inlet Pressure (inches W
.C.)
.............
11.5”
5.5”
Input Rate on “LO” (BTU/Hr)
.......
22,600
29,000
Maximum Inlet Pressure (inches W
.C.)
............
13”
7”
........................................................
Manifold Pressure on “HI” (inches W
.C.)
........
11
”
3.5”
This appliance is equipped for installation in USA, 0-2000 ft. (0-610 m).
In USA, for altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See the owner
’s
manual for information on making these changes.
Manufacture
2000
Jan.
Apr
.
Jul.
Oct.
Date:
2001
Feb.
May
Aug.
Nov
.
2002
Mar
.
Jun.
Sep.
Dec.
Report No. 028-S-20b-1
Minimum Clearances to Combustibles
Faceplate to
Adjacent W
all . . . . . . . . . . . .
4-1/2” (1
15mm)
Hearth Extension in Front - 16” (406mm), 0” (0mm) if Fireplace
Raised 3” (76mm)
W
ood Floor Beneath Fireplace
. . . . . . . .
0” (0mm)
Hearth Extension to Sides of Faceplate
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
0” (0mm)
Back to enclosure (from stand-offs)
. . .
0” (0mm)
Sides to enclosure (from stand-offs)
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
0” (0mm)
Top to enclosure (from stand-offs)
. . . . .
0” (0mm)
Faceplate to 8” Deep Mantel - 22” (558mm) for Rectangular Faces, 24” (610m
m) for
Arched Faces*
Flue V
ent
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. .
See Owner
’s
Manual
* See Owner
’s
Manual For
Additional Mantel Clearances and Options.
0322