Installation instructions, Gas supply connection, Gas regulator – Fisher & Paykel GC36 User Manual
Page 6
6
Gas supply connection
This appliance is factory set for use with
Natural Gas at 4” of water column pressure.
It can also be used on LP Gas at 11” of water
column pressure after conversion (see pages
7 & 8).
A manual shut-off valve must be installed
in an accessible location in the gas line
external to the appliance for the purpose
of turning on or shutting off gas to the
appliance. (In Massachusetts such shutoff
devices should be approved by the Board of
State Examiners of Plumbers & Gas Fitters).
Gas Regulator
For use with a gas pressure regulator as
shown below. The regulator supplied can
be set for either LP gas or Natural gas.
Installation Instructions
Blue washer
Elbow
Cooktop
To Cooktop
Regulator
Solid or Flexible
Connector
Shut-Off
Valve
Pipe Stub from
House supply
Pressure
Regulator
shows
Direction of
Gas Flow
Gas connection to the product must use
the elbow supplied with a
1
/
2
” NPT external
thread.
Ensure the blue washer (supplied) is
located between the elbow and the
product inlet. Failure to use this will
cause a gas leak.
(Note: this diagram is of GC36 but is similar for GC912 and
GC912M).