beautypg.com

Installation instructions, Gas supply connection, Gas regulator – Fisher & Paykel GC36 User Manual

Page 6

background image

6

Gas supply connection

This appliance is factory set for use with

Natural Gas at 4” of water column pressure.
It can also be used on LP Gas at 11” of water
column pressure after conversion (see pages
7 & 8).

A manual shut-off valve must be installed

in an accessible location in the gas line
external to the appliance for the purpose
of turning on or shutting off gas to the
appliance. (In Massachusetts such shutoff
devices should be approved by the Board of
State Examiners of Plumbers & Gas Fitters).

Gas Regulator

For use with a gas pressure regulator as

shown below. The regulator supplied can
be set for either LP gas or Natural gas.

Installation Instructions

Blue washer

Elbow

Cooktop

To Cooktop

Regulator

Solid or Flexible

Connector

Shut-Off

Valve

Pipe Stub from

House supply

Pressure

Regulator

shows

Direction of

Gas Flow

Gas connection to the product must use

the elbow supplied with a

1

/

2

” NPT external

thread.

Ensure the blue washer (supplied) is

located between the elbow and the
product inlet. Failure to use this will
cause a gas leak.

(Note: this diagram is of GC36 but is similar for GC912 and
GC912M).