Dynamic Characteristics at 5.5 in. Design Height

(Required for Airmount isolator design only)

Volume @ 80 PSIG = 20 in

3

Gage

Spring

Pressure

Load

Rate

(PSIG)

(lbs.)

(lbs./ in.)

40

150

55

113

1.88

60

220

70

107

1.78

80

290

91

105

1.74

100

380

99

95

1.59

Description

Assembly Order No.

Blind nut, 1/8 NPT

WO2-358-4001

Assembly weight ........................................................ 1.0 lbs.

Natural

Frequency

CPM

HZ

4

3

2

1

0

9

8

7

6

5

4

MAX. HT.

MIN. HT.

Volume
80 Psig

60 Psig

20 Psig

100 Psig

80 Psig

40 Psig

4

3

2

1

0

4

3

2

1

0

3 . 6

Do not use Airstroke in
shaded area without
consulting Firestone

CONSULT FIRESTONE

BEFORE USING AS

AIRMOUNT

RECOMMENDED

AIRMOUNT

DESIGN HEIGHT

5.5 INCHES

Static Data

8611

HEIGHT IN.

HEIGHT

3.1 MAX O.D.

AT 80 PSIG

15-20 FT. LBS.

TORQUE

3/8-16 THREADED HOLE

(3/4 DEEP)

1.65 DIA.

1/8 NPT

AIR INLET

1.38 DIA.

.50

NOTE: Bellows will not compress properly with less
than 10 PSIG internal pressure.

See page 12 for instructions on how to use chart.

V

OLUME (WITHOUT B

UMPER) CU IN. x 10

FORCE LBS x 100

Style
4001

Two

Ply

Bellows

Force Table (Use for Airstroke

®

actuator design)

Volume

Pounds Force

Assembly

@ 80

Height

PSIG

@20

@40

@60

@80

@100

(in.)

(in

3

)

PSIG

PSIG

PSIG

PSIG

PSIG

7.0

26

80

160

230

320

410

6.0

22

80

160

220

300

400

5.0

18

70

150

210

290

370

4.0

14

60

140

200

270

340

81