Furuno 1623 User Manual
Page 39

SP - 2
E3510S01C
4.3
Range, Range Interval, Number of Rings
Range (nm/km)
0.125 0.25
0.5 0.75
1
1.5
2
3 4 6 8 12 16 24
Ring Interval
0.0625 0.125 0.125 0.25 0.25 0.5 0.5 1 1 2 2 3 4 6
Number of Rings
2
2
4
3
4
3
4
3 4 3 4 4 4 4
Range unit: nm/sm/km selectable, 0.125: nm/sm only, 24: km only
4.4
Markers
Heading Line, Bearing Scale, Range Rings,
Variable Range Marker (VRM), Electronic Bearing Line (EBL),
Tuning Bar, Cursor, Parallel Cursor, Alarm Zone,
Waypoint Mark*, North Mark*
4.5
Alphanumeric Indications Range, Range Ring Interval, Display Mode (HU),
Interference Rejection (IR), Variable Range Marker (VRM),
Electronic Bearing Line (EBL), Stand-by (ST-BY),
Guard Alarm (G (IN), G (OUT), UP RANGE), Echo Stretch (ES),
Range and Bearing to Cursor, Bearing or L/L Position,
Echo Tailing (TRAIL), Trailing Time, Trailing Elapsed Time,
Watchman (WATCHMAN), Zoomed Display (ZOOM),
Navigation Data*, Heading* (HDC) *: external data required
4.6
Input Sentences
IEC61162, NMEA0183 (Ver1.5/2.0)
GGA, RMC, RMA, GLL, VTG, VBW, VHW, HDT, HDG, HDM,
BWR, BWC, GLC, GTD, DPT, DBK, DBS, DBT, MTW, ZDA,
MWV, XTE
4.7
Output Sentences
IEC61162, NMEA0183 (Ver3.0)
TLL (by key operation)
5
ENVIRONMENTAL CONDITION
5.1
Ambient Temperature
Scanner Unit: -25°C to +70°C, Display Unit: -15°C to +55°C
5.2
Relative Humidity
95 % or less at +40°C
5.3
Waterproofing
Scanner Unit: IPX6,
Display Unit: IPX5 (IPX0 when an external buzzer installed)
5.4
Bearing Vibration
IEC60945
6
POWER SUPPLY
12-24 VDC: 3.3-1.4 A
7
COATING COLOR
7.1
Display Unit
N3.0
7.2
Scanner Unit
Cover: N9.5, Bottom: 2.5PB 3.5/10
8
COMPASS SAFE DISTANCE
8.1
Display Unit
Standard: 0.50 m
Steering: 0.30 m
8.2
Scanner Unit
Standard: 1.25 m
Steering: 0.95 m