Dimensions and clearances – Follett VU155N Series User Manual
Page 5
Dimensions and clearances
Required clearances
51" (1295mm) minimum above counter for installation if dispenser will be dropped into counter
36" (915mm) minimum above counter for all units after installation for auger cleaning and servicing
12" (305mm) minimum on side opposite ice chute for service
12" (305mm) minimum on ice chute side if ice transport tube enters this side
12" (305mm) minimum between dispenser side(s) and optional icemaker(s)
*DO NOT
CONNECT TO
DRAIN SYSTEM
6"
min
27.375"
(696mm)
ice transport
Side View
Front View
tube entrance
6"
(153mm)
25.8"
(656mm)
bin
signal
power
8.75"
(223mm)
3/4 PVC
slip joint
drain
3/4 PVC slip
joint drain
18.5"
(470mm)
beverage
waterbath
overflow
beverage
drain pan
drain
3.5"
(889mm)
17"
(432 mm)
18.875"
(479mm)
18.875"
(479mm)
air break*
electrical
connections
21.75"
(553mm)
28"
(712mm)
counter top
ice
transport
tube
49.75"
(1264mm)
12"
min
31.25
12"
(305mm)
(794mm)
"
plain
water
Manual load unit
Dispenser with 1 optional auto-fill icemaker kit(s)
Dispenser with 2 optional auto-fill icemaker kit(s)
5