Specifications – FUJITSU RY-36UA User Manual
Page 2

(m
3
/hr)
FAN MOTOR
POWER SOURCE
(V)
230
DISCRIMINATION
MFA-45DZM
HI-SPEED
(r.p.m.)
1,000
INDOOR UNIT
MED-SPEED
(r.p.m.)
900
LO-SPEED
(r.p.m.)
750
OUTDOOR
DISCRIMINATION
MFB-30PTT X 2
UNIT
HI-SPEED
(r.p.m.)
780
2005.07.29
1
SPECIFICATIONS
TYPE
COOLING
COOLING & HEATING
INDOOR UNIT
RY-36FA
RY-36UA
OUTDOOR UNIT
RO-36FA
RO-36UA
COOLING CAPACITY
(kW)
10.5
HEATING CAPACITY
(kW)
-------
11.80
POWER SOURCE
FREQUENCY
50Hz
COOLING
6.20
5.90
RUNNING CURRENT (A)
HEATING
-------
6.20
INPUT WATTS
(kW)
COOLING
3.74
3.48
HEATING
-------
3.45
E.E.R.
(kW/kW)
COOLING
2.81
3.02
HEATING
-------
3.42
MOISTURE REMOVAL
4.0
AIR CIRCULATION
1,660
TYPE
Hermetic type, 2 poles, 3 phase,
Twin Rotary
DISCRIMINATION
5JD420PAA02
ELECTRICAL DATA
COMPRESSOR
( /hr)
ADDITIONAL REFRIGERANT CHARGE (R410A)
PIPE LENGTH
20 m
2,000 g
3,200 g
FULL CHARGE
30 m
2,300 g
3,500 g
AMOUNT
40 m
2,600 g
3,800 g
50 m
2,900 g
4,100 g
ADDITIONAL CHARGE
30 g/m
MAX PIPE HEIGHT
30
MAX PIPE LENGTH
(m)
(m)
50
INDOOR UNIT
H x W x D
(mm)
H x W x D
(mm)
240 x 1,660 x 700
OUTDOOR UNIT
1,165 x 900 x 330
DIMENSIONS
INDOOR UNIT
GROSS / NET
GROSS / NET
(kg)
(kg)
61 / 48
OUTDOOR UNIT
87 / 80
101 / 94
WEIGHT
3N 400V