Table 13. remote switch functions, Operation with remote controls, Table 14. operation with remote controls – Fusion F300S User Manual
Page 60: Quick restart option (qro)

60
F300S/F300SQ Ultraviolet Lamp System
2. Turn the Master POWER switch ON and press the LAMP ON switch.
3. The system will now operate from remote switches. Remote switch functions are
virtually the same as front panel switch functions.
Operation with Remote Controls
KEY:
S- Switch position does not matter.
Quick Restart Option (QRO)
The Quick Restart Option (QRO) provides the ability to restart the lamp at any time,
even immediately after the lamp has been switched to Standby mode. Thus, the
mandatory 18-second restart cycle time associated with routine operation has been
eliminated. The QRO may be installed at the time of the P300MQ power supply
construction or may be retrofitted into P300M power supplies in the field by trained
personnel.
Table 13. Remote Switch Functions
Remote Switch
Equivalent Panel
Control
Lamp Status
Switch Open
Switch Closed
Lamp ON
Lamp ON
Standby
Lamp ON
Lamp RESET
LAMP OFF/RESET
Default to lowest state
LAMP OFF/RESET
Table 14. Operation with Remote Controls
Panel Controls on Master
Remote
Switches
Power
Lamp Control
Lamp ON
Lamp Status
Off/Reset
S
S
Off/Reset
ON
LAMP OFF/RESET
S
LAMP OFF/RESET
ON
ON
Remote RESET
Switch CLOSED
LAMP OFF/RESET
(overrides remote Lamp
ON switch)
ON
STANDBY
OPEN
STANDBY
CLOSED
ON
OPEN
CLOSED
Lamp ON