1.3.5 Signal Routing Capability
The A Channel of all three types of television inputs (composite, Y/C and Component) may be independently re-
routed to the B-channel enabling pass through of the A signal to the B connector.
1.3.6 Control Methods
Front Panel Keyboard
IR Remote (Supplied)
RS-232/422 (cable ordered as an Accessory)
DB-9 Male
1.3.7 Power Consumption
Desktop Unit:
13-20 VDC
20W
Unit is shipped with a 13 Volt DC power supply, center positive, 2.5 mm barrel connector (male side on the unit). At 13
V., the desktop unit consumes a maximum of 1.5 A.
Rackmount Unit:
120 V.
0.25 A.
240 V.
0.15 A.
1.3.8 Physical Size
Desktop Unit:
7.5" X 7.25" X 2.0”"
Rackmount Unit:
19.0” X 10.0” x 1.75” (rack mount brackets installed)
17.0” X 10.0” x 1.75” (rack mount brackets not installed)
1.3.9 Environmental
Desktop Unit:
Operating Temperature:
0 to 40 degrees Celsius
Storage Temperature:
-40 to 125 degrees Celsius
Humidity:
0 to 90%, non-condensing
Rackmount Unit:
Operating Temperature:
0 to 40 degrees Celsius
Storage Temperature:
-40 to 125 degrees Celsius
Humidity:
0 to 90%, non-condensing