Specifications, Electrical, Plumbing – Follett U155BX User Manual
Page 5
Specifications
Electrical
Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each.
Model
Icemaker
Dispenser
number
amperage
amperage
Single-sided models
U155, U155X
2.4 amps
U155B, U155BX
4.4 amps
U155R400A/W, U155R400A/WX
11.0 amps
2.4 amps
U155BR400A/W, U155BR400A/WX
11.0 amps
4.4 amps
U155R800A/W, U155R800A/WX
11.0 amps ea (2)
2.4 amps
U155BR800A/W, U155BR800A/WX
11.0 amps ea (2)
4.4 amps
Plumbing
Dispenser
3/4" PVC pipe nipple for bin drain
3/4" PVC pipe nipple for drain pan drain
1" ID hose for beverage bath drain
Beverage connections
1/4" ID syrup beverage hose
3/8" ID carbonated water beverage hose
3/8" ID plain water beverage hose
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.
Icemaker
(detailed specifications may be found in icemaker installation manual
packed with icemaker)
3/8" OD push-in water in
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
5