Frymaster SR52 & SR62 User Manual
Page 8
SUPER RUNNER SERIES GAS FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
1-6
Frypot Assembly
Gas Valve
Manifold Support Bracket
Gas Burner
See Detail A
Pressure
Test
Spigot
Orifice
Temperature
Control
Gas
Manifold
Assembly
1/2—3/4 Reducer
Bushing
Burner
Gas Manifold
Burner/Orifice Location
Detail A
Orifice
1.30-inch [33-mm]
1.63-inch [41-mm]
1.6 Gas Conversion Components
Use the following components to convert from natural gas to propane and vice-
versa. See Section 1.5 for orifice quantities required for conversion.
Natural Gas to Propane Components
Propane To Natural Gas Components
REF DESCRIPTION* REF DESCRIPTION*
810-2400
Pilot Orifice (16LP) CE & Non-CE
810-0811
Pilot Orifice (26N) CE & Non-CE
810-2059
Burner Orifice, 1.51mm- CE ONLY:
All Super Runner Series
810-2060
Burner Orifice, 2.40mm- CE ONLY:
All Super Runner Series
810-2059
Burner Orifice, 1.51mm (#53)- NON-
CE ONLY: SR52 & SR62 Series Only
810-2048
Burner Orifice, 2.53mm (#39)- NON-
CE ONLY: SR52 & SR62 Series Only
810-2064
Burner Orifice, 1.70mm (#51)- NON-
CE ONLY: SR42 Series Only
810-2040
Burner Orifice, 2.80mm (#35)- NON-
CE ONLY: S42 Series Only
New Rating
Label
Contact factory at time of
conversion. PN 802-2144
New Rating
Label
Contact factory at time of
conversion. PN 802-2144
* Burner orifices listed above are for fryers operating at altitudes of 2000 feet (610 meters) or less. For altitudes
greater than 2000 feet (610 meters), contact the factory for the correct orifice size.
Typical gas valve, burner and orifice locations (SR42 shown above).
Propane Applications:
Proper Regulator Must Be Installed