Follett Horizon HCE1000AJS User Manual
Page 8
8
self-contained
DROP-IN • SATELLITE-FILL
Install the louvered docking assembly.
Louvered docking assembly
4
DOCKING STATION: Horizon 1000 & 1400 water- and air-cooled models
(See detail drawing on page 9)
• Position and screw louvered docking assembly to the bottom of counter inside of access
panel/door 1.75" (45mm) from the front edge of the cross brace
➊
• The mounting surface for the louvered docking assembly must be solid.
Do not mount directly onto runners or channels.
• There must be no lip or edge that would hinder the icemaker from sliding in or out of the
louvered docking station
➋
INTAKE AND EXHAUST GRILLE PLACEMENT: Horizon 1000 & 1400 air-cooled models only
(See detail drawing on page 9)
• Position the intake grille cut out in the access panel/door
Note: Icemaker must be aligned with cut out and inside of access panel to provide a tight
seal and prevent recirculation of hot exhaust air.
• Left edge of cutout should be 1.75" (45mm) from the left side of the icemaker
➌
• Bottom edge of cutout should be 1.875" (48mm) from the bottom of the icemaker
➍
• Position supplied exhaust grille at least 18" (458mm) away from intake grille
➎
.
Where possible, install exhaust grille to the rear or side of the base cabinet.
• If not using supplied grille, air circulation requirements below must be met:
1000 series: 150 sq. in (967 sq cm) intake air, 150 sq. in (967 sq. cm) exhaust air
1400 series: 175 sq. in (1129 sq. cm) intake air, 175 sq. in (1129 sq. cm) exhaust air
Undercounter installation requirements Horizon 1000 & 1400 series
4.1
WARNING
• Docking station must be secured in accordance with these instructions to ensure icemaker stability.
• Ventilation openings in the louvered docking station should be clear of obstruction
Wall bracket accessory
Machine stand accessory
• Mount louvered docking assembly to wall
bracket accessory
• Mount louvered docking assembly to
machine stand accessory