3
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces risk of electric
shock by providing an escape wire for the electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The oven must be plugged into at least 15 amp, 120 volts, 60 Hz grounded outlet. It is recommended that a
separate circuit serving only the oven be provided. The oven is equipped with a 3-prong grounding plug. It must be
plugged into a wall receptacle that is properly installed and grounded.
Extension Cord
We do not recommend to use an extension cord. If it is necessary to use an extension cord, use only a 3-wire
extension cord that has a 3 blade grounding plug and a 3-slot receptacle that will accept the plug on the
microwave oven. The marked rating of the extension cord shall be equal to or greater than the electrical rating of
the appliance.
Notes: 1. If you have any questions about the grounding or electrical instructions, consult a qualified electrician
or service person.
2. Neither Haier nor the dealer can accept any liability for damage to the oven or personal injury resulting
from failure to observe the electrical connection procedures.
Radio or TV Interference
Should there be any interference caused by the microwave oven to your radio or TV, check that the microwave
oven is on a different circuit, relocate the radio or TV as far away from the oven as feasible or check position and
signal of recieving antenna.
INSTALLATION INSTRUCTIONS
Select a level surface that provides enough open space for the intake and/or outlet vents. A minimum clearance of
3 inches is required between the oven and any adjacent wall. One side must be open. Leave a minim clearance of
3 inches above the oven. Do not cover or block any openings on the appliance. Do not remove feet from the
bottom of the oven.
English