1-3. TROUBLESHOOTING
(Continued)
Problem
Cause
Correction
Green compressor indicator
Voltage across terminals 10-11
light off and compressor
of control board:
is working
- Control board relay bad
Replace control board
No voltage across terminals 10-11
of control board:
- Faulty contactor
Replace contactor
Green fan indicator light
Voltage across terminals 8-9 of
on and fan(s) not working
control board.
- Fan or capacitor bad
Replace fan or its capacitor
- Fan thermo-switch tripped
Allow the fan motor to cool to
see if the fan comes back on;
if the fan does not come back
on, or it keeps tripping, re-
place the fan
No voltage across terminals 8-9
of control board:
- Faulty control board relay
Replace control board
All indicator lights off and
Check electrical supply
Plug unit into receptacle, or
ON/OFF switch will not
reset wall circuit breaker
operate
Fuse of control board blown
Change the fuse
No voltage from the control
Change the control board
board transformer
Connector between the control
Check the connection
board and display board not
connected properly
Bad wire in the connector between
Replace the connector
the control board and display
board