beautypg.com

Panasonic KX-TD500 User Manual

Page 342

background image

Programming Error Messages

342

Programming Guide

E1006

You have exceeded the system limit of AGC cards.
There is a limit of 8 AGC cards per system.

E1007

You have exceeded the system limit of remote cards.
One RMT card or one ERMT card can be installed in the system -- only one.

E1008

You have exceeded the system limit of DPH cards.
There is a limit of two DPH/DPHG cards per system.

E1009

The slot next to a T1 card must be empty.
Please remove and re-assign the card that is installed next to a T1 card. A T1 card must
go into slot no.1, 5 or 9.

E1010

You must change card type to None, before changing to new card type.
This process is required to make sure that all data for previous card is deleted.

E1011

The card of clock configuration priority duplicated.
Each card must have a unique priority.

E1012

The status of the card is not INS (In-Service).
To use this port, you must put the card INS (In-Service).
When the card is INS (In-Service) status, all the ports of the card become in service.

E1013

Cannot change the attribute of the port which is the paired extension of a DSS
console.
The attribute of this port cannot be changed until it is de-assigned as the paired
extension of a DSS console. Please change the attribute after de-assignment.

E1014

You have exceeded the system limit of DSS consoles.
There is a limit of 64 consoles per system.

E1015

Incomplete directory number.
The DN and FDN must be 3 or 4 digits.

E1016

Invalid directory number.
The entered DN doesn't match the numbering plan in "2-2 Numbering Plan" screen.

E1017

Directory number already exists.
The entered DN or FDN already exists.

E1018

Directory number doesn't exist.
The entered DN doesn't exist.

E1019

Invalid directory number for paired extension of DSS console.
Only the DN of PT can be assigned as the DN for the paired extension of a DSS
console.

E1020

You have exceeded the limit of DSS consoles per PT.
There is a limit of 8 DSS consoles per PT.

E1022

Assign the directory number before making the port INS (In-Service) status.
An extension without a DN cannot be placed into service.

Error Code

Error Message

Description