C. Check Firebrick
Frequency: After each ash removal
By: Homeowner
D. Inspect Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
• Warping or sagging 1-1/2 in. (38 mm) or more
• Broken welds
• Burn-through of grate bars
For safe operation, replace only with an approved grate
from Hearth & Homes Technologies Inc.
WARNING! Risk of Fire! Inspect firebrick. Crumbling,
deteriorated firebrick can allow overheating of surround-
ing materials.
Expansion and contraction will cause minor cracking of
the firebrick. This is normal. The firebrick will require peri-
odic replacement depending on use.
• Replace broken firebrick.
E. Glass Cleaning
Frequency: As desired
By: Homeowner
Clean glass with a non-abrasive commercially available
cleaner or ashes:
• Light deposits
- Use household glass cleaner
• Heavy deposits
- Use wood ash on damp cloth or,
- Use commercial fireplace glass cleaner (consult with
your dealer)
CAUTION! Handle glass assembly with care. Glass is
breakable.
• Avoid striking, scratching or slamming glass
• Avoid abrasive cleaners
•
DO NOT clean glass while it is hot
Heatilator • SC60 • 32838 • Rev AG • 7/12