Xx x gsc, Technical data, Example: gsc c 01 b – Honeywell GSS Series User Manual
Page 6: Ordering, 1/2" npt = 20 mm
202
•
Industrial Safety Products •
GSS Series
* Point from which the positive opening is assured
** Positive opening occurs at operating position. But to meet IEC/EN 60947-5-3
which requires a dielectric gap of 2,5 kV, positive opening is assured at*.
Note: See page 197
Low Energy Contacts
GSC EN 50047
Safety Metal
Standard
Technical Data
Mechanical
up to 15 million
life
operations
Degree of
IP 66
protection
NEMA/UL
type 1, 4, 12, 13
Temperature
Operating:
range
-25 °C to +85 °C /
-13 °F to +185 °F
Storage:
-40 °C to +85 °C /
-40 °F to +185 °F
Approvals*
IEC 60947-5-1
EN 60947-5-1
ac15 A300
dc13 Q300
BG, UL & CSA
Vibration
10 g conforming to
IEC 68-2-6
Shock
50 g conforming to
IEC 68-2-27
Terminal marking to EN 50013
*See Standards (page 179)
Snap-Action Contacts
Slow-Action Contacts
1 NORMALLY CLOSED/
2 NORMALLY CLOSED
1 NORMALLY OPEN
Circuit closed
*Positive opening to IEC/EN 60947-5-1-3
XX
X
GSC
A
C
= 1/2" NPT
= 20 mm
Conduit
Thread
Ordering:
01
Example: GSC C 01 B
GSS
(F.P.)
-4,4
21-22
13-14
21-22
13-14
15 mm
43,3
DT = 9,8 mm
RP = 5,2 mm
(O.P.)
26˚
0˚
(R.P.)
14,5˚
(D.T.)
11,5˚
(
*
)
54˚
(O.T.)
61˚ to 75˚
FP
OP
OT
*
21 mm
OP 18 mm
16 mm
15 mm
21-22
13-14
21-22
13-14
FP
18,9 mm
RP
DT =
0,9 mm
OT
(max.)
*
5,3 mm
21-22
13-14
21-22
13-14
13,9
10,5
FP
OT
1,6 DT
*
8,9 RP
(F.P.)
0˚
(O.P.)
26˚
(R.P.)
(D.T.)
(
*
)
46,5˚
(O.T.)
61˚ to 75˚
-4,4
15 mm
36,5
FP
*
OT
21-22
11-12
21 mm
18 mm
16,5 mm
15 mm
(max.)
FP
*
OT
21-22
11-12
5,3 mm
10,5 13,5
FP
*
OT
21-22
11-12
Note: Incorporates safety screws
24,75 /
0.97
14,5 /
0.57
30 /
1.18
conduit
thread
ш 23 /
ш 0.9
19,8 /
0.78
22 /
0.87
20 /
0.78
3 /
0.12
2,15 /
0.08
R
55 /
2.16
30,5 /
1.20
3,5 /
0.138
Dimensions in mm / in
13
21
14
22
Zb
21
11
22
12
2Y
36